RC vs RH on a Thermostat: What These Wires Mean and How to Connect Them
Pull an old thermostat off the wall and you’ll find a small row of lettered terminals — and, confusingly, two of them seem to do the same job. There’s an RC terminal and an RH terminal, both meant for a red wire. If your old thermostat only has one red wire, which terminal does it go to? And what’s that little metal clip bridging the two together?
The RC vs RH question stops more DIY thermostat swaps than almost any other wiring puzzle. The good news: once you know what each terminal does, the answer is simple — and you’ll wire your new thermostat without losing heat or AC.
The Quick Answer
RC receives 24-volt power from the cooling side of your HVAC system. RH receives the same 24-volt power from the heating side. The letters give it away: “R” is the red power wire, “C” stands for cooling, and “H” stands for heating.
Some thermostats have a single terminal labeled just R — designed for systems where one power source feeds both heating and cooling, which describes most modern homes.
Here’s what matters most: if your home has one transformer, RC and RH are connected by a small jumper. If it has two transformers, they must stay completely separate. Everything else flows from that one distinction.
What RC and RH Actually Do
Your thermostat doesn’t run on the 120-volt power that feeds your lights and outlets. It switches a low-voltage control circuit — 24 volts AC — supplied by a transformer inside your furnace, air handler, or boiler.
When you set the thermostat to cool, it internally connects the RC terminal to the Y terminal, sending the 24-volt signal to your air conditioner or heat pump. When you call for heat, it connects RH to the W terminal instead, sending power to the furnace or boiler.
So RC and RH are the two power inputs: RC powers the cooling call, RH powers the heating call. If one has no power connected, that half of your system won’t respond — even though the thermostat screen lights up and everything looks fine.
One Transformer or Two? Why Both Terminals Exist
Single-transformer systems (most homes)
In most homes, one piece of equipment — usually the furnace or air handler — contains a single transformer supplying 24-volt power for both heating and cooling. Only one red wire comes out of the wall, and because it has to feed both terminals, RC and RH are joined by a jumper so the single power source reaches both sides of the thermostat.
Dual-transformer systems (less common)
Some homes have genuinely separate heating and cooling equipment — a boiler for heat, for example, and a separate air handler for cooling. Each unit has its own transformer, so two red wires come out of the wall: one from the heating transformer, one from the cooling transformer.
Those two power sources are not synchronized and must be kept electrically separate — which is exactly why the thermostat provides two distinct terminals. In a dual-transformer setup, RC gets the cooling transformer’s wire, RH gets the heating transformer’s wire, and there is no connection between them.

The Jumper Wire: Small Clip, Big Consequences
The jumper is a small metal staple or short piece of wire bridging RC and RH. Many thermostats ship with it pre-installed. Its only job is to share one transformer’s power across both terminals.
When the jumper must stay: If you have a single-transformer system — one red wire — the jumper must be in place (or your new thermostat must handle the connection internally). Without it, power reaches only one terminal. The classic symptom: the air conditioning works but the heat never kicks on, or the reverse.
When the jumper must never be installed: If you have a dual-transformer system, never connect RC and RH together. Bridging two unsynchronized transformers can create a surge that damages the transformers, blows the low-voltage fuse, or fries the control board. This is the one mistake in this job that can actually break equipment, so treat it seriously.
How to Tell Which System You Have
You don’t need a multimeter or an HVAC background. You just need to look — safely — and count.
Turn the thermostat mode to Off, pull the thermostat body off its wall plate, and look at the terminals before touching any wires. Take a clear photo showing the terminal letters and wire colors, then check what you see against this table:
| What you see | What it means | What to do |
|---|---|---|
| One red wire on RC or RH, with a jumper or clip between the two terminals | Single transformer feeding both heating and cooling | Keep the jumper arrangement on the new thermostat |
| One red wire on a single R terminal | Single transformer; the thermostat doesn’t split the terminals | Connect the red wire to R (or RC, per the new manual) |
| Two red wires — one on RC, one on RH — and no jumper | Dual transformer, one for each system | Keep them separate; do not add a jumper |
| Two red wires and a jumper in place | Two power sources incorrectly bridged | Stop and call an HVAC technician — this can damage equipment |
That count — one red wire or two — is the most useful thing your photo will tell you.
Wiring a New Thermostat: Step by Step
Before you start
- Turn the power off at the breaker. Switch off the breaker for the furnace or air handler before touching any wires. The wiring is low voltage, but a short can still blow the control board’s fuse.
- Photograph the old wiring. Get every terminal letter and wire color in one clear shot — your backup if anything goes wrong.
- Label the wires with the stickers included with your new thermostat. Wire colors aren’t always standard — trust the terminal letters, not the colors.
If you have a single-transformer system
- Connect the red wire to RC on the new thermostat (some models say to use R — follow the manual).
- Make sure the jumper between RC and RH is in place, unless the new thermostat connects them internally with a switch or slider.
- Connect the remaining wires to the same terminals they used before: typically W for heat, Y for cooling, G for the fan, and C if you have a common wire.
If you have a dual-transformer system
- Connect the red wire that came off RC to RC, and the one from RH to RH. Label them before removing so they don’t get mixed up.
- Remove the jumper if the new thermostat shipped with one installed, and confirm any internal RC/RH switch is set to “separate” or “2-wire” mode.
- Connect the remaining wires to their matching terminals, exactly as before.
When everything is connected, mount the thermostat, restore power at the breaker, and test both modes: run the heat for a few minutes, then the cooling, and confirm the right equipment responds in each mode.
RC and RH on Smart Thermostats
Smart thermostats handle the RC/RH split in their own ways — and there’s often no visible jumper at all, which trips many people up.
Google Nest thermostats have a single Rc terminal on most models — you connect your red wire there whether it came from RC or RH on the old unit, and Nest handles the rest internally. Its compatibility checker will flag the rare dual-transformer setup that needs professional help.
Ecobee thermostats also use one Rc terminal for the power wire. If you have two red wires from a dual-transformer system, ecobee directs you to connect the cooling-side wire to Rc and the heating-side wire to Rh on models that provide both — check your model’s wiring guide before you start.
Honeywell models vary the most. Many use a small slider switch or a built-in jumper clip for “1-wire” or “2-wire” setups. Set it to match your system: one transformer means the terminals stay linked; two means the switch separates them.
Whichever brand you choose, run through the manufacturer’s online compatibility checker with your photo of the old wiring in hand. It takes five minutes and prevents most mistakes.
Common Mistakes to Avoid
- Removing the jumper on a single-transformer system. The result is a thermostat that runs one mode perfectly and ignores the other. If your heat or AC stopped working right after a swap, check this first.
- Jumpering a dual-transformer system. The opposite error, and the expensive one — it can damage transformers and control boards.
- Mixing up the two red wires on a dual system. Swap the heating and cooling power wires and you’ll get crossed behavior: a call for heat may try to run the cooling equipment. Label them before removal.
- Trusting wire colors instead of terminal letters. Installers don’t always follow color conventions, especially in older homes. The letter a wire was connected to is the only label that matters.
- Skipping the breaker. One slipped wire can blow the low-voltage fuse and leave you with no heat until it’s replaced.
When to Call an HVAC Pro
Most thermostat swaps are straightforward DIY, but call a licensed HVAC technician if:
- You find two red wires and a jumper already installed.
- Your wiring doesn’t match anything in the new manual — for example, wires labeled with numbers instead of letters, which usually means an older proprietary system.
- The new thermostat powers up but the equipment doesn’t respond in one or both modes after you’ve double-checked the jumper and connections.
- You’re adding a C wire or changing anything beyond a like-for-like swap.
A service call costs far less than a control board, and a tech can confirm your transformer setup in minutes.
Frequently Asked Questions
Can I connect one red wire to either RC or RH?
Yes — in a single-transformer system, the red wire can go on either terminal as long as the jumper connects RC and RH, since the jumper shares the power with the other terminal. Without the jumper, only the side with the wire will work.
What happens if I remove the jumper by mistake?
On a single-transformer system, one half of your system loses power: the heat or the air conditioning stops responding while the other works normally. Reinstall the jumper (breaker off) and both should come back.
Do I need a C wire for a new thermostat?
Many modern and smart thermostats need a C (common) wire for continuous power. If your old thermostat ran on batteries and has no C wire, check whether your new model offers a power adapter kit, or have a pro run one.
Why does my thermostat have only an R terminal?
Because it’s built for single-transformer systems, where one power feed serves both heating and cooling. A single R terminal does the same job as RC and RH joined by a jumper.
Can RC and RH wires be swapped?
On a single-transformer system it makes no difference, since both terminals share one power source. On a dual-transformer system, swapping them crosses the heating and cooling power supplies and can cause the wrong equipment to run — keep each wire on its original terminal.
Bottom line: RC powers the cooling side, RH powers the heating side, and the jumper between them belongs in exactly one situation — a single-transformer home with one red wire. Count your red wires, take a photo, kill the breaker, and the rest is just matching letters.